- New
- Out Of Stock - info [email protected]
XBS-PK11
LINKEDPRO BY EPCOM KLP-TZ03-PRO Lightning Rod Kit LINKEDPRO with Tower Installation Accessories up to 3 m high
Climate change is one of the main causes of the increase in storm activity and lightning strikes and therefore of the appearance of so many accidents in facilities not protected against atmospheric discharges.
Description:
Manufactured with copper with electrolytic treatment to obtain higher conductivity low resistance and durability in aggressive terrain. Due to its delta-shaped design it obtains a greater contact area with the ground and thus to be able to efficiently dissipate parasitic currents. Equipotential filter which has the property of damping low frequencies minimizing noise preventing the passage of return currents and equipotentially bonding natural electrodes as well as prefabricated on site. Soil reactivating compound which is composed of conductive minerals to lower soil resistivity and improve the performance of the grounding system.
Made of aluminum. Provides protection VS direct lightning strikes to surfaces or structures. It provides a safe point of impact as the toroidal exciter coil and equipotential ring create an ionization effect (corona) which will provide an attractive point for lightning strike. This tip connected to the down conductor will provide a safe path to the SEPTE grounding electrode to drain the lightning current. It has an approximate coverage radius of 72 degrees.
Applications:
The grounding system is the essential part of any electrical installation and its objective is:
- Provide security to people.
- Protect infrastructure electrical and electronic equipment.
- Protect installations.
- Guarantee the operation of this protection.
- Stabilize the voltage.
- Dissipate the lightning current.
- Limit transient overvoltages. (Voltage Peaks).
- Drain static charges that the metallic masses present with respect to the ground.
Standards:
It complies with telecommunications standards as well as official Mexican standards.
- EIA/TIA J-STD-607-A y BICSI
- NOM-022-STPS-2012
- NOM-022-STPS-2015
- NMX-J-549-ANCE-2005
Includes the following components:
LIGHTNING ROD PROTECTION SYSTEM | |||||
Qty. | U | Model | Description | ||
1 | Pc. | LP-DIPOLO-ALU | Aluminum Crown Dipole Lightning Rod Tip | ||
1 | Pc. | LP-GROUND-30A | 30 A Electrode with Filter and Compound Bag | ||
3 | Pcs. | LP-CB-20 | 1/2 Terminal Connectors to Cables Gauge 4 to 1/0 (AWG). | ||
2 | Pcs. | LP-CV-20 | 5/8 Rod Connector to 4 Gauge Cable (Four) to 3/0 (Triple Zero) | ||
1 | Pc. | LP-REGISTRO-7 | Round Valve Box 7" | ||
1 | Pc. | LP-ANTICORROSIVO | Antioxidant protective spray for electrical connections. | ||
2 | Pcs. | LP-AISLADOR-UNI | Insulator for Bare Cable Grounding Systems in STZ30 and STZ30G Towers | ||
8 | m | SLY343-BLK | THW-LS Coated Copper Wire Gauge 1/0 AWG Color Black (1 METER) | ||
PHYSICAL GROUND SYSTEM FOR EQUIPMENT AND STRUCTURES LANDING | |||||
Qty. | U | Model | Description | ||
1 | Pc. | LP-GROUND-30A | 30 A Electrode with Filter and Compound Bag | ||
5 | Pcs. | LP-CB-20 | 1/2 Terminal Connectors to Cables Gauge 4 to 1/0 (AWG). | ||
2 | Pcs. | LP-CV-20 | 5/8 Rod Connector to 4 Gauge Cable (Four) to 3/0 (Triple Zero) | ||
1 | Pc. | LP-REGISTRO-7 | Round Valve Box 7" | ||
1 | Pc. | LP-CTZ-114 | 5/8 Rod Connector to 4 Gauge Cable (Four) to 3/0 (Triple Zero) | ||
1 | Pc. | LP-BU-TZ | Grounding cooper bar. Pipe installation. | ||
5 | m | SLY287-GRN | Coated Copper Wire THW-LS Gauge 4 AWG 19 Wires Green Color |
2024-10-22 13:25:55
Page: 5
KLPTZ03PRO LINKEDPRO BY EPCOM Lightning Rod Kit LINKEDPRO with Tower Installation Accessories up to 3 m high KLP-TZ03-PRO
Reviews
No customer reviews for the moment.