KIT-RF-SFIRE-2
KITRFSFIRE2 SFIRE KIT SFIRE RF Sensors - 2 magnetic contact SFWST232 / 1 PIR SFWST702 / 1 Keyfob SFWST102 KIT-RF-SFIRE-2
ALTRONIX AL400ULACM Access Power Controller w/ Power Supply/Charger 8 Fused Relay Outputs 12/24VDC 4A FAI 115VAC BC400 Enclosure With backup battery capacity Requires battery
Power supply for access control backup capacity for 12 and 24 Vdc 4 A 8 control circuits (NO) and 8 trigger circuits 8 Fail-Safe outputs and / or Fail Secure 8 relay outputs C voltage entry of: 115 Vca
Input
- Input 115VAC 60Hz rated 3.5A.
- Power supply input options:
a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power (external power supply is required). (Current is determined by the power supply connected not to exceed a maximum of 10A total).
- Eight (8) Access Control System trigger inputs.
-
Input options:
a) Eight (8) normally open (NO) inputs. - b) Eight (8) open collector inputs.
- c) Any combination of the above.
Output
- 12 VDC or 24VDC outputs.
- 12VDC 4A supply current or 24VDC 3A supply current.
- Class 2 Rated power limited outputs.
- Eight (8) independently controlled outputs.
-
Output options:
-
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
b) Eight (8) form "C" 5A rated relay outputs.
b) Eight (8) form "C" 5A rated relay outputs.
c) Any combination of the above.
Eight (8) auxiliary power outputs (unswitched)
Output ratings:
- Eight (8) independently controlled outputs.
- Fuses are rated 3.5A.
- Filtered and electronically regulated outputs (built-in power supply).
- ACM8 board main fuse is rated at 10A.
Supervision
- AC fail supervision (form "C" contacts). Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
- Low battery and battery presence supervision (form "C" contact).
Features
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Fire Alarm disconnect input options:
- a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated 1A 28VDC not evaluated by UL).
- Short circuit and thermal overload protection.
-
Visual Indicators
- Short circuit and thermal overload protection.
- Red LEDs indicate outputs are triggered (relays energized).
- Green LED indicates FACP disconnect is triggered.
- AC input and DC output LED indicators.
-
Battery Backup
- AC input and DC output LED indicators.
- With backup battery capacity.
- Battery is not included.
- The battery can be: PL4.512 / PL712 / PL912.
- Built-in charger for sealed lead acid or gel type batteries.
- Automatic switch over to stand-by battery when AC fails.
- Zero voltage drop when unit switches over to battery backup (AC failure condition).
- Battery fail and battery presence supervision (form "C" contact).
-
Temperature - Battery fail and battery presence supervision (form "C" contact).
- Operating: 0ºC to 49ºC (32ºF to 120ºF).
- Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).
- Relative Humidity 85% /- 5%.
BTU/Hr. (approx.):
- Relative Humidity 85% /- 5%.
- 12VDC: 25 BTU/Hr.
- 24VDC: 37 BTU/Hr.
Enclosure
- Wall mount enclosure for indoor use.
- Accommodates up to two (2) 12VDC/12AH Batteries.
- Dimensions 12.25"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D).
- 1.125" and 1.375" combination knockouts.
Weights (approximate)
- Product Weight: 10.7 Lbs. (4.85 kg).
- Shipping Weight: 12 Lbs. (5.44 kg).