ALTRONIX AL400ULACM Access Power Controller w/ Power Supply/Charger 8 Fused Relay Outputs 12/24VDC 4A FAI 115VAC BC400 Enclosure With backup battery capacity Requires battery
Power supply for access control backup capacity for 12 and 24 Vdc 4 A 8 control circuits (NO) and 8 trigger circuits 8 Fail-Safe outputs and / or Fail Secure 8 relay outputs C voltage entry of: 115 Vca
Input
- Input 115VAC 60Hz rated 3.5A.
- Power supply input options:
a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power (external power supply is required). (Current is determined by the power supply connected not to exceed a maximum of 10A total).
- Eight (8) Access Control System trigger inputs.
-
Input options:
a) Eight (8) normally open (NO) inputs. - b) Eight (8) open collector inputs.
- c) Any combination of the above.
Output
- 12 VDC or 24VDC outputs.
- 12VDC 4A supply current or 24VDC 3A supply current.
- Class 2 Rated power limited outputs.
- Eight (8) independently controlled outputs.
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
b) Eight (8) form "C" 5A rated relay outputs.
c) Any combination of the above.
Eight (8) auxiliary power outputs (unswitched)
Output ratings:
- Eight (8) independently controlled outputs.
- Fuses are rated 3.5A.
- Filtered and electronically regulated outputs (built-in power supply).
- ACM8 board main fuse is rated at 10A.
Supervision
- AC fail supervision (form "C" contacts). Notification trigger is selectable for 30 seconds (factory set) or 6 hours.
- Low battery and battery presence supervision (form "C" contact).
Features
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Fire Alarm disconnect input options:
- a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit.
- Alarm output relay indicates that FACP input is triggered (form "C" contact rated 1A 28VDC not evaluated by UL).
- Short circuit and thermal overload protection.
-
Visual Indicators
- Short circuit and thermal overload protection.
- Red LEDs indicate outputs are triggered (relays energized).
- Green LED indicates FACP disconnect is triggered.
- AC input and DC output LED indicators.
-
Battery Backup
- AC input and DC output LED indicators.
- With backup battery capacity.
- Battery is not included.
- The battery can be: PL4.512 / PL712 / PL912.
- Built-in charger for sealed lead acid or gel type batteries.
- Automatic switch over to stand-by battery when AC fails.
- Zero voltage drop when unit switches over to battery backup (AC failure condition).
- Battery fail and battery presence supervision (form "C" contact).
-
Temperature
- Battery fail and battery presence supervision (form "C" contact).
- Operating: 0ºC to 49ºC (32ºF to 120ºF).
- Storage: - 20ºC to 70ºC ( - 4ºF to 158ºF).
- Relative Humidity 85% /- 5%.
BTU/Hr. (approx.):
- Relative Humidity 85% /- 5%.
- 12VDC: 25 BTU/Hr.
- 24VDC: 37 BTU/Hr.
Enclosure
- Wall mount enclosure for indoor use.
- Accommodates up to two (2) 12VDC/12AH Batteries.
- Dimensions 12.25"W x 15.5"H x 4.5"D (311 mm W x 394 mm H x 114 mm D).
- 1.125" and 1.375" combination knockouts.
Weights (approximate)
- Product Weight: 10.7 Lbs. (4.85 kg).
- Shipping Weight: 12 Lbs. (5.44 kg).