COM-3010

0 Review(s) 
COM3010 RAMSEY RAMSEY Radiocommunications Service Monitor 100 KHz - 1.0 GHz 100 W max COM-3010
RAMSEY
COM-3010
Sorry, This item is out of stock.

COM-3010 RAMSEY RAMSEY Radiocommunications Service Monitor 100 KHz - 1.0 GHz 100 W max


Radiocommunications Service Monitor 100 KHz-1.0 GHz 100 W max.
Now you can equip your laboratory with your monitor that has the functions and accuracy of analyzers that cost up to 4 times more.

  • Power Meter: Automatically connects to a dummy load build-in for measurements up to 100 Watts
  • Screen: 2 Graphic Fluorescent Screens to the void 16 x 140 pixels 
  • Flash Drives: Complete system for Flash drives 100 sequences of 100 records 
  • Mode of Scan: Allows the tracking of 100 stored frequencies
  • Meter of SINAD: Verifies the sensibility of your radios without requiring additional equipment
  • Counter of Frequency: It shows the frequency received and the error of range
  • of 100 kHz 3 - 1.0 GHz
  • Battery Meter: It shows on the screen the charge of the battery the one that allows operation of the equipment during an hour
  • Self-calibration Meter of RSI: It shows the intensity signal (RSSI) within a range of - 120 dBm to - 40 dBM

GENERATOR MODE

  • Frequency: 100 kHz - 1.0 GHz in steps of 1 Hz
  • Stability: ± 0.1 ppm standard
  • Output: RF: -140 dBm to 0 dBm in steps of 0.1 dBm
  • Precision: ± 1 dB of 500 kHz to 1 GHz ± 2 dB of 100 kHz to kHz
  • Units: dBm mV
  • Modulation FM: ± 75 kHz plus in steps of 0.1 Hz
  • AM Bandwidth: 10 Hz - 10 kHz
  • Precision: ± 5%
  • Distortion: less to 5%

Modulations

  • Internal: 0.1 Hz - 3 kHz
  • External: 0.1 Hz - 3 kHz
  • Coding of tones CTCSS: 0.1 Hz - 999.9 Hz with a deviation of frequency variable of 0.1 Hz to 2 kHz 
  • Coding of tones DCS: Generates the standard digital tones  with a fixed deviation of ± 750 Hz

RECEPTOR MODE

  • Frequency: 100 kHz - 1.0 GHz in steps de 10 Hz
  • Sensibility: Less to 2 mV below of 512 MHz less to 3 mV up to 512 MHz
  • Modulation FM: 0 - 7 kHz 0-4 kHz 
  • Modulation AM 0-100%
  • Decoding CTSS: (in auto frequency count)
  • Frequency error: 0-1 MHz by 2 methods. Counter and bar graph

Frequency Count

  • Range: 100 kHz - 1 GHz
  • Low band Sensibility: Less to 5 mV below 50 MHz less to 10 mV above 70 MHz resolutions of 1 Hz and 10 Hz
  • High band Sensibility: Less to 6 mV above 200 MHz less to 10 mV between 70 and 200 MHz. Resolutions from 10 Hz to 100 Hz

General Features

  • Input to the receiver: Contains diode protection and fuse
  • Battery duration: 1.5 hours expandable to 4.5 hours
  • Controls: Membrane elastic type
  • Dummy load: 100 Watts connected to the output of RF and the output. attenuated of 30 dB in the backside 25 % d endless cycle to 100 Watts
  • Power Supply: 100 - 240 VAC 0.6 Amp. 50/60 Hz: In-build internal battery 
  • Operating Temperature: -30 to 50° C

2024-02-23 11:55:17

Page: 4

RAMSEY
COM-3010

Reviews

No customer reviews for the moment.

Write your review

COM-3010

COM3010 RAMSEY RAMSEY Radiocommunications Service Monitor 100 KHz - 1.0 GHz 100 W max COM-3010

Write your review