- New
- Out Of Stock - info [email protected]
TPCP-4546
TPCP4546 TELEWAVE INC Band-Pass Preselector 400-512 MHz 6 Cavities of 4" Diameter 4 MHz Bandwidth N Females. TPCP-4546
RAMSEY COM-3010 RAMSEY Radiocommunications Service Monitor 100 KHz - 1.0 GHz 100 W max
Radiocommunications Service Monitor 100 KHz-1.0 GHz 100 W max.
Now you can equip your laboratory with your monitor that has the functions and accuracy of analyzers that cost up to 4 times more.
- Power Meter: Automatically connects to a dummy load build-in for measurements up to 100 Watts
- Screen: 2 Graphic Fluorescent Screens to the void 16 x 140 pixels
- Flash Drives: Complete system for Flash drives 100 sequences of 100 records
- Mode of Scan: Allows the tracking of 100 stored frequencies
- Meter of SINAD: Verifies the sensibility of your radios without requiring additional equipment
- Counter of Frequency: It shows the frequency received and the error of range
- of 100 kHz 3 - 1.0 GHz
- Battery Meter: It shows on the screen the charge of the battery the one that allows operation of the equipment during an hour
- Self-calibration Meter of RSI: It shows the intensity signal (RSSI) within a range of - 120 dBm to - 40 dBM
GENERATOR MODE
- Frequency: 100 kHz - 1.0 GHz in steps of 1 Hz
- Stability: ± 0.1 ppm standard
- Output: RF: -140 dBm to 0 dBm in steps of 0.1 dBm
- Precision: ± 1 dB of 500 kHz to 1 GHz ± 2 dB of 100 kHz to kHz
- Units: dBm mV
- Modulation FM: ± 75 kHz plus in steps of 0.1 Hz
- AM Bandwidth: 10 Hz - 10 kHz
- Precision: ± 5%
- Distortion: less to 5%
Modulations
- Internal: 0.1 Hz - 3 kHz
- External: 0.1 Hz - 3 kHz
- Coding of tones CTCSS: 0.1 Hz - 999.9 Hz with a deviation of frequency variable of 0.1 Hz to 2 kHz
- Coding of tones DCS: Generates the standard digital tones with a fixed deviation of ± 750 Hz
RECEPTOR MODE
- Frequency: 100 kHz - 1.0 GHz in steps de 10 Hz
- Sensibility: Less to 2 mV below of 512 MHz less to 3 mV up to 512 MHz
- Modulation FM: 0 - 7 kHz 0-4 kHz
- Modulation AM 0-100%
- Decoding CTSS: (in auto frequency count)
- Frequency error: 0-1 MHz by 2 methods. Counter and bar graph
Frequency Count
- Range: 100 kHz - 1 GHz
- Low band Sensibility: Less to 5 mV below 50 MHz less to 10 mV above 70 MHz resolutions of 1 Hz and 10 Hz
- High band Sensibility: Less to 6 mV above 200 MHz less to 10 mV between 70 and 200 MHz. Resolutions from 10 Hz to 100 Hz
General Features
- Input to the receiver: Contains diode protection and fuse
- Battery duration: 1.5 hours expandable to 4.5 hours
- Controls: Membrane elastic type
- Dummy load: 100 Watts connected to the output of RF and the output. attenuated of 30 dB in the backside 25 % d endless cycle to 100 Watts
- Power Supply: 100 - 240 VAC 0.6 Amp. 50/60 Hz: In-build internal battery
- Operating Temperature: -30 to 50° C
2024-10-22 13:25:25
Page: 3
COM3010 RAMSEY RAMSEY Radiocommunications Service Monitor 100 KHz - 1.0 GHz 100 W max COM-3010
Reviews